Status of the CO2 laser ion source at CERN

Citation
P. Fournier et al., Status of the CO2 laser ion source at CERN, REV SCI INS, 71(2), 2000, pp. 924-926
Citations number
6
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
REVIEW OF SCIENTIFIC INSTRUMENTS
ISSN journal
00346748 → ACNP
Volume
71
Issue
2
Year of publication
2000
Part
2
Pages
924 - 926
Database
ISI
SICI code
0034-6748(200002)71:2<924:SOTCLI>2.0.ZU;2-A
Abstract
A laser ion source using a CO2 laser focused onto a solid target is under s tudy at CERN for the production of high currents of highly charged heavy io ns, for possible use in the preinjector for the large hadron collider. A ne w expansion and extraction layout was installed in this test facility, impr oving the alignment and making the target to extraction distance more flexi ble. A two solenoid beam transport system was studied for providing the mat ching of the beam to a radio-frequency quadrupole. An electrostatic beam tr ansport using gridded electrostatic lenses was designed and constructed as an alternative to a magnetic system. Results show an increased overall curr ent transmission for the electrostatic case. Investigation of the laser par ameters required for the production of 1.4x10(10) Pb25+ ions in a 5 mu s pu lse, has been performed using the TIR-1 laser facility at power densities u p to 10(14) W cm(-2) for a focal spot size of 65 mu m. The results of the l atest scaling are presented. (C) 2000 American Institute of Physics. [S0034 -6748(00)53102-5].