M. Gilany et al., Field experience with settings and coordination of the protective devices in a developed oil field plant, ELEC MACH P, 28(2), 2000, pp. 143-152
This paper is concerned with updating the protective device settings and co
ordination in an existing developed large industrial oil plant. Problems of
short circuit carrying capacity of the system equipment, existence of diff
erent protection systems, and outdoor dropout fuses, as well as guidelines
for some protective devices, are considered. This paper gives in steps the
proper procedure to deal with such problems in a developed industrial plant
.