Separation of carrier-free Tm-163,Tm-165 produced in 80 MeV O-16 irradiated Eu2O3 target matrix

Citation
D. Nayak et al., Separation of carrier-free Tm-163,Tm-165 produced in 80 MeV O-16 irradiated Eu2O3 target matrix, RADIOCH ACT, 87(1-2), 1999, pp. 75-78
Citations number
17
Categorie Soggetti
Inorganic & Nuclear Chemistry
Journal title
RADIOCHIMICA ACTA
ISSN journal
00338230 → ACNP
Volume
87
Issue
1-2
Year of publication
1999
Pages
75 - 78
Database
ISI
SICI code
0033-8230(1999)87:1-2<75:SOCTPI>2.0.ZU;2-F
Abstract
Radiothulium is potential candidate in the field of nuclear medicine. In vi ew of this, carrier-free Tm-163,Tm-165 isotopes have been produced by the a ctivation of natural Eu2O3 with 80 MeV O-16 beam. Radiochemical separation of produced thulium isotopes from the bulk target matrix of europium oxide has effectively been carried out by liquid-liquid extraction using HDEHP as liquid cation exchanger.