The posterior slope of tibial plateau in 25 pairs of Chinese cadaveric tibi
a was studied. A digital photograph of the lateral profile of each cadaveri
c tibia was taken, and the posterior slope angles of medial and lateral pla
teau relative to the anterior tibial cortex were measured. The posterior sl
ope of the medial plateau was 14.8 degrees, and the posterior slope of the
lateral plateau was 11.8 degrees. Lateral radiographs of each cadaveric tib
ia were taken, and the posterior tibial slope angles relative to simulated
extramedullary and intramedullary alignment were determined. With radiograp
hic measurement, the posterior slope was 11.5 degrees using intramedullary
method, and it was 14.7 degrees using extramedullary method. The posterior
slopes increased with the presence of degenerative changes.