Degradation of phenol in aqueous solution by TiO2 photocatalyst coated rotating-drum reactor

Citation
A. Toyoda et al., Degradation of phenol in aqueous solution by TiO2 photocatalyst coated rotating-drum reactor, J CHEM EN J, 33(1), 2000, pp. 188-191
Citations number
8
Categorie Soggetti
Chemical Engineering
Journal title
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
ISSN journal
00219592 → ACNP
Volume
33
Issue
1
Year of publication
2000
Pages
188 - 191
Database
ISI
SICI code
0021-9592(200002)33:1<188:DOPIAS>2.0.ZU;2-K
Abstract
In order to commercialize a photochemical reactor for treatment of biohazar d organic compounds in aqueous solution, a film-shaped photocatalyst compos ed of platinum-loaded TiO2/water glass/substrate was fabricated, immobilizi ng pretreated TiO2 powders on a substrate plate by a double spread method. A new type of photocatalytic reactor, called a TiO2 photocatalyst coated ro tating-drum reactor, was proposed, in which the surface of the drum is the reaction site so that the photocatalyst can effectively contact aqueous sol ution and receive light. A experiment in decomposing phenol in an aqueous s olution using this reactor was carried out. In consequence, it is shown tha t phenol can be decomposed in a relatively short time, not only under artif icial ultraviolet light, but also under solar light.