Ja. Jonsson et al., Automated liquid membrane extraction for high-performance liquid chromatography of Ropivacaine metabolites in urine, J CHROMAT A, 870(1-2), 2000, pp. 151-157
An automatic method for the determination of metabolites of Ropivacaine in
urine was set up. It utilizes supported liquid membrane extraction for samp
le clean-up and enrichment, followed by ion-pair chromatography determinati
on using UV detection. The extraction was very selective with no observed i
nterfering compounds from the urine matrix, permitting simple isocratic chr
omatographic analysis. The detection limits for spiked urine samples were 2
-18 nM for the different compounds. The repeatability was 1-3% (RSD) with a
n internal standard that was also extracted, and about twice without this s
tandard. A throughput of 3.3 samples per hour was achieved and the liquid m
embrane was stable for more than a week. (C) 2000 Elsevier Science BN. All
rights reserved.