G. Castelli et al., Detection of anti-erythropoietin antibodies in haemodialysis patients treated with recombinant human-erythropoietin, PHARMAC RES, 41(3), 2000, pp. 313-318
An enzyme-immunoassay was developed to evaluate the presence of anti-erythr
opoietin antibodies in:plasma samples obtained from renal failure patients
treated with recombinant human erythropoietin (rh-EPO). The assay was speci
fic and reproducible. Normal donors had no antibodies to EPO, while 67% of
treated patients were positive to the assay. While the specificity of anti-
EPO IgG antibodies was high, their affinity for the antigen was low. This f
inding can be explained by the very small differences in the structure of r
h-EPO compared to that of natural EPO. The assay described could be useful
in evaluating the long-term effects of rh-EPO treatment on the control of a
naemia in renal failure patients. (C) 2000 Academic Press.