Acoustic power flow measurement in a thermoacoustic resonator by means of laser Doppler anemometry (LDA) and microphonic measurement

Citation
H. Bailliet et al., Acoustic power flow measurement in a thermoacoustic resonator by means of laser Doppler anemometry (LDA) and microphonic measurement, APPL ACOUST, 60(1), 2000, pp. 1-11
Citations number
21
Categorie Soggetti
Optics & Acoustics
Journal title
APPLIED ACOUSTICS
ISSN journal
0003682X → ACNP
Volume
60
Issue
1
Year of publication
2000
Pages
1 - 11
Database
ISI
SICI code
0003-682X(200005)60:1<1:APFMIA>2.0.ZU;2-#
Abstract
Acoustic power flow measurements in the resonator of a thermoacoustic refri gerator are described. The technique of measurement is based on particle ve locity measurement by laser Doppler anemometry (L.D.A.) together with micro phonic acoustic pressure measurement. The calibration procedure is explaine d and results of measurements are compared with analytical results. The L.D .A. technique permits the measurement of acoustic power flow at almost any position and for almost any working frequency in the resonator of thermoaco ustic devices. (C) 2000 Elsevier Science Ltd. All rights reserved.