D. Ortelli et al., Enantioselective analysis of methadone in saliva by liquid chromatography-mass spectrometry, J CHROMAT A, 871(1-2), 2000, pp. 163-172
Saliva was tested and evaluated as a biological matrix for methadone (Mtd)
monitoring. Conventional method using a narrow bore C-18 column, and an ena
ntioselective method using a narrow bore alpha(1)-acid glycoprotein column,
were developed using liquid chromatography coupled with a mass spectromeri
c (MS) detector. After optimisation of MS conditions by flow injection anal
ysis, selected ion monitoring detection was used to enhance sensitivity. Th
e total Mtd concentration and the enantiomeric ratio in saliva were validat
ed using an experimental design. The methods were applied to samples provid
ed by heroin addicts undergoing a Mtd treatment. Results on total Mtd deter
mination showed a very poor correlation between saliva and serum, whereas t
he enantiomeric ratios of Mtd gave a very good one. (C) 2000 Elsevier Scien
ce B.V. All rights reserved.