A new type of multi-point multi-wavelength pyrometer for solid propellant r
ocker engine flame distribution measurement was developed successfully. The
instrument can record the radiation fluxes of 8 wavelengths for uniformly
distributed 6 points on the target surface, which are well defined by the h
oles on the field stop lens. The fast-response pyrometer with the specially
designed synchronous data acquisition system can assure that the recorded
thermal radiation fluxes of different spectrum region are of the same time
and the same true temperature even with dramatically changed targets.