C. Lu et Y. Peiyu, An algorithm of galvanostatic pulse method to determine the corrosion status of reinforcement in concrete, CORROS SCI, 42(4), 2000, pp. 675-686
An algorithm was developed to Fourier-transform the measuring data of galva
nostatic pulse method (GPM) from the time domain into the frequency domain.
The polarization resistance and ohmic resistance are determined in the tim
e domain; the impedance spectrum and disperse parameter are obtained in the
frequency domain to characterize the corrosion status of reinforcement in
concrete. Based on the investigation upon the different corrosion status of
rebars in solution and in concrete, the criterions of depassivation are di
scussed. (C) 2000 Elsevier Science Ltd. All rights reserved.