Comparison of digestion methods for the determination of selenium in fish tissue by cathodic stripping voltammetry

Citation
Df. Lambert et Nj. Turoczy, Comparison of digestion methods for the determination of selenium in fish tissue by cathodic stripping voltammetry, ANALYT CHIM, 408(1-2), 2000, pp. 97-102
Citations number
21
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences
Journal title
ANALYTICA CHIMICA ACTA
ISSN journal
00032670 → ACNP
Volume
408
Issue
1-2
Year of publication
2000
Pages
97 - 102
Database
ISI
SICI code
0003-2670(20000309)408:1-2<97:CODMFT>2.0.ZU;2-8
Abstract
A certified reference material (NIST-RM-50 Albacore Tuna) was analysed for selenium by cathodic stripping voltammetry (CSV), after digestion of the ma terial by a number of methods that avoid the use of perchloric acid. The di gestion techniques tested included wet and dry ashing methods, oxygen bomb digestion, ultraviolet (UV) digestion, and methods involving elevated press ure. The only method that reliably produced results that agreed with the certifi ed value for selenium in the reference material was the combination wet/dry ashing method incorporating elevated pressure recommended by the Associati on of Official Analytical Chemists (AOAC) for determination using hydride g eneration atomic absorption spectrometry (AAS). Recoveries using the other methods were low and variable, apparently because of incomplete destruction of organic matter and losses caused by volatilisation of selenium. (C) 200 0 Elsevier Science B.V. All rights reserved.