L. Feenstra et al., On the performance of an ArF and a KrF laser as a function of the preionisation timing and the excitation mode, APP PHYS B, 70(2), 2000, pp. 231-235
An X-ray preionised ArF and KrF excimer laser has been studied with three d
ifferent spiker-sustainer excitation circuits. We observed large difference
s in the laser performance, when the preionisation delay timing was varied
on a nanosecond timescale. The behaviour of both lasers was found to be equ
ivalent. The observations can be understood by considering the effect of th
e discharge excitation technique on the preionisation process. An excitatio
n mode with a prepulse well above the steady-state voltage Vss with a subse
quent reversed overshoot voltage for initiating the discharge, in combinati
on with a well-timed preionisation pulse is found to give the best results.
Optimum output energies of 50 mJ with ArF and 175 mJ with KrF were obtaine
d from an active volume of 60 x 1.5 x 1.2 cm in the so-called swing mode, w
ith the preionisation applied 60 ns before the discharge breakdown.