The present study examines the performance difference between straight and
coiled capillary tubes. The test results indicate that the helical effect i
ncreased with decrease of the diameter of coiling, and the effect of inlet
conditions is relatively small. Based on the present test results, a simple
relation is proposed which can quantitatively describe the difference betw
een coiled and straight capillary tubes.