I. Meyer et al., QUALITATIVE AND QUANTITATIVE RENAL-FUNCTI ON TESTING IN THE DOG BY MEANS OF MAG(3)-CLEARANCE MEASUREMENT, Berliner und Munchener Tierarztliche Wochenschrift, 110(5), 1997, pp. 185-189
In the presented study Tc-99m-MAG(3) clearance measurements were under
taken in 14 dogs during renal scintigraphic examination. Of these dogs
, 10 showed no renal impairment, the other 4 exhibited clinically mani
fested nephropathy. It was the aim of these examinations to determine
if this type of clearance measurement that is routinely used in human
medicine is suitable for diagnosis of canine nephropathy. An algorithm
for the calculation of the MAG(3)-Clearance developed for humans was
modified. The clearance measurement can be performed during the renal
scintigraphic procedure without any difficulties. In the group of dogs
with no renal impairment the clearance values ranged between 6.4 and
8.0 ml/min/kg, whereas in the group of patients exhibiting nephropathi
es the values ranged between 2.0 and 2.7 ml/min/kg. The suitability of
the method for its use in dogs needs to be confirmed with higher pati
ent numbers. In addition, further studies are necessary to precisely a
ssess the correlation between measured clearance values and effective
renal plasma flow in dogs.