Complete luxation of the polyethylene inlay after internal hemipelvectomy and custom made endoprothesis.

Citation
Tk. Lichtinger et al., Complete luxation of the polyethylene inlay after internal hemipelvectomy and custom made endoprothesis., Z ORTHOP GR, 138(1), 2000, pp. 57-59
Citations number
4
Categorie Soggetti
Ortopedics, Rehabilitation & Sport Medicine
Journal title
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE
ISSN journal
00443220 → ACNP
Volume
138
Issue
1
Year of publication
2000
Pages
57 - 59
Database
ISI
SICI code
0044-3220(200001/02)138:1<57:CLOTPI>2.0.ZU;2-0
Abstract
We report about an exceptional complication after internal hemipelvectomy a nd replacement of the defect with a custom-made endoprosthesis.:A complete luxation of the PE-inlay out of the metal cup occurred. Radiologically we a ssumed a luxation of the femoral head in dorsal direction. Revision after a failed attempt of closed reposition showed a complete luxation of the inla y, which was caused by deficient fixation in the acetabular component. The absence of a contrast wire in the PE-inlay delayed the right diagnosis and made it difficult to find the dislocated inlay in the large wound.