Determination of the urethral dose in prostate brachytherapy when the urethra cannot be visualized in the postimplant CT scan

Citation
Fm. Waterman et Ap. Dicker, Determination of the urethral dose in prostate brachytherapy when the urethra cannot be visualized in the postimplant CT scan, MED PHYS, 27(3), 2000, pp. 448-451
Citations number
8
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Medical Research Diagnosis & Treatment
Journal title
MEDICAL PHYSICS
ISSN journal
00942405 → ACNP
Volume
27
Issue
3
Year of publication
2000
Pages
448 - 451
Database
ISI
SICI code
0094-2405(200003)27:3<448:DOTUDI>2.0.ZU;2-3
Abstract
This study investigates the feasibility of locating the urethra at the geom etric center of peripherally loaded I-125 prostate implant when a urinary c atheter is not utilized for the postimplant CT scan. Twenty postimplant CT scans utilizing a urinary catheter were randomly selected. The urethra was localized in each study and, in addition, a surrogate urethra was localized at the geometric center of the prostate. Dose-volume histograms of the ure thra and surrogate urethra were compiled and compared. The values obtained for the urethra D-10, D-25, and D-50 were in good agreement and demonstrate that the urethral dose can be determined reliably by locating a surrogate urethra at the geometric center of the prostate in a peripherally loaded im plant when the urethra cannot be visualized. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01403-6].