The range of several heavy ions as U-238, Pb-208, (197)AU, La-139, Ni-58 an
d Fe-56 in sodalime glass; (197)AU and Ni-58 in muscovite mica and Lexan po
lycarbonate; Bi-209 and (197)AU in CR-39 have been determined experimentall
y. The calculations of range for these projectile-target combinations have
been made using the Benton and Henke [10], Mukherjee and Nayak [11], Ziegle
r et al. [12] and Hubert et al. [14] semiempirical formulations. Finally a
comparison has been made with the experimental results. (C) 2000 Elsevier S
cience B.V. All rights reserved.