O. Cudina et al., Determination of fluocortolone pivalate and fluocortolone hexanoate in suppositories using reverse-phase HPLC, FARMACO, 55(2), 2000, pp. 125-127
Fluocortolone and its esters are synthetic corticosteroids used topically i
n the treatment of various skin disorders. A method that can be successfull
y used for the separation and determination of fluocortolone pivalate and f
luocortolone hexanoate in suppositories was developed. This method is based
on reverse-phase HPLC on Supelcosil LC-18 (25 cm x 4.6 mm, 5 mu m), using
methanol-acetonitrile-water-glacial acetic acid (17: 46:37:0.4 v/v/v/v) as
mobile phase at a flow rate of 3.0 ml/min. Detection was carried out using
a UV detector at 238 nm. The method developed was validated, and calibratio
n curves were established dependent on peak area. The validated ranges for
fluocortolone pivalate and fluocortolone hexanoate are 15-305 mu g/ml (r =
0.9995) and 15-315 mu g/ml (r = 0.9996), respectively. The limits of detect
ion and the limits of quantification for both eaters were also determined.
(C) 2000 Elsevier Science S.A. All rights reserved.