Seismic analysis of the HIFAR nuclear reactor secondary coolant pipework and associated inlet and outlet headers

Citation
P. Bendeich et W. Payten, Seismic analysis of the HIFAR nuclear reactor secondary coolant pipework and associated inlet and outlet headers, INT J PRES, 77(2-3), 2000, pp. 133-138
Citations number
5
Categorie Soggetti
Mechanical Engineering
Journal title
INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING
ISSN journal
03080161 → ACNP
Volume
77
Issue
2-3
Year of publication
2000
Pages
133 - 138
Database
ISI
SICI code
0308-0161(200002)77:2-3<133:SAOTHN>2.0.ZU;2-2
Abstract
A seismic analysis was carried out to examine the integrity of the secondar y coolant circuit within the reactor containment building for the HIFAR rea ctor located at Lucas Heights. Eigen evaluations of the structure for the f irst 40 modes were determined for a number of piping configurations. A resp onse spectrum for a 0.2g earthquake was then used to excite the structure a nd the resulting stresses were examined for areas of potential failure. (C) 2000 Elsevier Science Ltd. All rights reserved.