R. Hirsch et al., A sensitive method for the determination of iodine containing diagnostic agents in aqueous matrices using LC-electrospray-tandem-MS detection, FRESEN J AN, 366(8), 2000, pp. 835-841
Iodinated contrast media belong to the most frequently applied compounds in
medicine. They exhibit a high polarity and are very persistent against met
abolism by the organism and environmental degradation. A sensitive method f
or the determination of five iodinated contrast media in aqueous matrices i
s described. Solid phase extraction utilizing Isolute ENV+ material was use
d for sample enrichment. The contrast media were partially separated on a R
P-C-18 column, and detection was achieved using electrospray-tandem MS (API
III plus and API 365) allowing the sensitive quantitation of these compoun
ds down to the lower ng/L range. The recovery rates generally exceeded 70%,
for spiked surface water as well as tap water. The analytes were detected
in native samples such as municipal sewage treatment plant (STP) effluent,
the river Rhine and even in tap water.