Purpose. To develop and evaluate a new method to quantify centration of the
trephined donor cornea relative to the limbus. Methods, After human donor
corneas were trephined for penetrating keratoplasty, the remaining corneosc
leral discs were stained and subjected to image analysis. The centration of
the excised donor cornea relative to the limbus was calculated by measurin
g their centroids from the "captured" images. Results. Fifty-two corneo-scl
eral discs were analyzed. The average deviation from the centre was 0.32 mm
(SD, 0.18 mm). Neither surgeon nor the type of trephine significantly infl
uenced the mean centroid deviation. Conclusion. We have developed and evalu
ated a method to quantify centration of human donor cornea. In a small seri
es, decentration did not correlate significantly with either the surgeon or
the trephine.