In this paper, the power input to the radiating element of an active micros
trip patch antenna is measured using a small sensing patch, which is weakly
coupled to a radiating edge. Combined with an estimate of patch radiation
efficiency, this also yields a measurement of total radiated power. The met
hod has advantages of convenience, insensitivity to room reflections, and a
weakly frequency-dependent calibration factor.