We show the possibility of noiseless amplification of an optical image in c
avities containing a parametric oscillator. We consider a confocal ring cav
ity with plane miners and compare with the case of planar cavity. ln the la
tter case the system operates with severe spatial limitations, while in the
confocal case, there is the possibility of preserving the signal-to-noise
ratio while amplifying uniformely the entire image.