Porcine liver uricase immobilized on alkylamine glass (pore diameter 55 nm)
through glutaraldehyde coupling has been found useful in the determination
of uric acid in urine. The minimum detection limit was 12.0 mu g/0.1 ml sa
mple and the recovery of added uric acid was 91%. The coefficient of variat
ion (CV) were <6.0% and <2.0% for within and between batch assay respective
ly. A good correlation (r=0.93) was found between urate values obtained by
a standard commercial method and the present method.