Feasibility studies of the self-TOF detector for high-energy neutron measurements in shielding experiments

Citation
M. Sasaki et al., Feasibility studies of the self-TOF detector for high-energy neutron measurements in shielding experiments, NUCL INST A, 446(3), 2000, pp. 545-554
Citations number
9
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
446
Issue
3
Year of publication
2000
Pages
545 - 554
Database
ISI
SICI code
0168-9002(20000521)446:3<545:FSOTSD>2.0.ZU;2-G
Abstract
The feasibility of a new type of neutron detector was studied. The detector consists of a radiator, a start counter and a stop counter. The radiator i s composed of 20 thin plastic-scintillation detectors and the stop counter is segmented into nine plastic-scintillation detectors. Neutrons impinging on the radiator emit charged particles. The time of flight of protons emitt ed at a forward angle is measured using the start and stop counters, theref ore, we call the detector the "self-TOF detector". The proton time-of-fligh t spectrum is converted to the energy spectrum of neutrons using a measured response function. The basic properties of the detector, such as detection efficiency, signal-to-noise ratio, particle identification capability, and energy resolution, were studied. (C) 2000 Elsevier Science B.V. All rights reserved.