C. Oliveira et al., Dose rate determinations in the Portuguese Gamma Irradiation Facility: Monte Carlo simulations and measurements, RADIAT PH C, 58(3), 2000, pp. 279-285
A simulation study of the Portuguese Gamma Irradiation Facility, UTR, has b
een carried out using the MCNP code. The work focused on the optimisation o
f the dose distribution inside the irradiation cell, dose calculations insi
de irradiated samples and dose calculations in critical points for protecti
on purposes.
Calculations were carried out at points inside and outside the irradiation
cell, where different behaviour was expected (distance from the source, rad
iation absorption and scattering in irradiator structure and walls). The co
ntributions from source, irradiator structure, sample material, carriers? w
alls, ceiling and floor to the photon spectra and air kerma at those points
are reported and discussed.
Air kerma measurements were also carried out using an ionisation chamber. G
ood agreement was found between experimental and calculated air kermas. (C)
2000 Elsevier Science Ltd. All rights reserved.