Salbutamol plastic membrane electrodes based on individual and mixed ion-exchangers of salbutamolium phosphotungstate and phosphomolybdate

Citation
Nt. Abdel-ghani et al., Salbutamol plastic membrane electrodes based on individual and mixed ion-exchangers of salbutamolium phosphotungstate and phosphomolybdate, ANALYST, 125(6), 2000, pp. 1129-1133
Citations number
34
Categorie Soggetti
Chemistry & Analysis","Spectroscopy /Instrumentation/Analytical Sciences
Journal title
ANALYST
ISSN journal
00032654 → ACNP
Volume
125
Issue
6
Year of publication
2000
Pages
1129 - 1133
Database
ISI
SICI code
0003-2654(2000)125:6<1129:SPMEBO>2.0.ZU;2-8
Abstract
Salbutamol (Sl), also known as albuterol, selective PVC membranes based on ion associates of salbutamolium phosphotungstate (Sl-PTA), salbutamolium ph osphomolybdate (Sl-PMA) or a mixture of both (Sl-PTA/PMA) were prepared. Th e electrodes displayed a linear response over the concentration range 6.3 x 10(-6)-1.0 x 10(-1) mol dm(-3) salbutamol sulfate (Sl(2)SO(4)). The workin g pH ranges of the above electrodes were 2.5-11.0, 3.0-11.0 and 2.5-10.5 an d their isothermal temperature coefficients were 0.00095, 0.00105 and 0.001 36 V degrees C-1, respectively. The electrodes showed good selectivity to s albutamolium ion with respect to many inorganic cations, sugars and amino a cids. The standard additions method was used to determine Sl(2)SO(4) in pur e solutions and pharmaceutical preparations with high accuracy and precisio n.