Purification of human prothrombin from Nitschmann fraction III using DEAE membrane radial flow chromatography

Citation
T. Sun et al., Purification of human prothrombin from Nitschmann fraction III using DEAE membrane radial flow chromatography, J CHROMAT B, 742(1), 2000, pp. 109-114
Citations number
11
Categorie Soggetti
Chemistry & Analysis
Journal title
JOURNAL OF CHROMATOGRAPHY B
ISSN journal
13872273 → ACNP
Volume
742
Issue
1
Year of publication
2000
Pages
109 - 114
Database
ISI
SICI code
1387-2273(20000526)742:1<109:POHPFN>2.0.ZU;2-2
Abstract
A DEAE membrane radial column (4x5 cm) was used to purify human prothrombin from Nitschmann fraction III and performances of the column were investiga ted. Sample flow-rate of 20-30 ml/min (i.e., 24-36 bed volumes/h) and eluti on velocity up to 40 ml/min (i.e., 48 bed volumes/h) were obtained without compromising the separation efficiency. Its breakthrough capacity was one-t hird to half that of the commercial DEAF Sepharose Fast Flow media. It was concluded that the novel column is an attractive alternate to traditional a xial column. (C) 2000 Elsevier Science B.V. All rights reserved.