Y. Nishi et al., Impression pressures against teeth in a partially edentulous model with a mobile tooth: influence of impression tray design, J ORAL REH, 27(5), 2000, pp. 380-386
The purpose of the present study was to examine the effect of custom tray d
esigns on local pressures against teeth during the impression procedure. In
a previous study, a partially edentulous simulation model with a mobile to
oth was used, and the effect of custom tray designs on the displacement of
the mobile tooth was examined during the impression procedure. Based on tha
t study's results, we have assumed that the differences in impression press
ures between the labial and the lingual sides of a mobile tooth could eithe
r cause or affect displacement. The present study was undertaken to determi
ne the local impression pressures against each side of three anterior teeth
, including one mobile tooth, using the same simulation model and the same
custom trays as in the previous study. It was found that the local pressure
s exerted against teeth during the impression procedure were affected by th
e custom tray designs and varied according to the coronal shape, axis Incli
nation and location of the teeth.