Detection of coronary sclerosis by new and established screening tests.

Citation
H. Ditlbacher et al., Detection of coronary sclerosis by new and established screening tests., PERFUSION, 13(5), 2000, pp. 204
Citations number
16
Categorie Soggetti
Cardiovascular & Respiratory Systems
Journal title
PERFUSION
ISSN journal
09350020 → ACNP
Volume
13
Issue
5
Year of publication
2000
Database
ISI
SICI code
0935-0020(200005)13:5<204:DOCSBN>2.0.ZU;2-F
Abstract
Non invasive detection of coronary sclerosis is one of the most important t opics in the evaluation of cardiac patients. Established and new screening tests were compared to the gold standard of coronary angiography in 50 pati ents. Electron beam computer tomography - evaluating the amount of coronary calcium - is able to detect localized and diffuse sclerotic lesions with h igh sensitivity compared to treadmill stress testing and nuclear scintigrap hy.