Determination of copper by an adsorption differential pulse stripping method with naphthol derivative

Citation
Aa. Ensafi et Ma. Naeeni, Determination of copper by an adsorption differential pulse stripping method with naphthol derivative, ANAL LETTER, 33(8), 2000, pp. 1591-1601
Citations number
15
Categorie Soggetti
Chemistry & Analysis","Spectroscopy /Instrumentation/Analytical Sciences
Journal title
ANALYTICAL LETTERS
ISSN journal
00032719 → ACNP
Volume
33
Issue
8
Year of publication
2000
Pages
1591 - 1601
Database
ISI
SICI code
0003-2719(2000)33:8<1591:DOCBAA>2.0.ZU;2-K
Abstract
A simple, sensitive and selective method is proposed for the determination of copper(II) by adsorption-differential pulse shipping method. This method is based on the selective accumulation of the complexes of Cu(II) with 1-( 2-pyridylazo)-2-Naphthol and then reduction of the complex on a HMDE. The r eduction current of the complex is about 0.0V vs. Ag/AgCl reference electro de at pH=4.0. The influences of various experimental parameters on the curr ent peak were completely studied. The calibration graph was linear up to 50 .0 ng/ml for a deposition time of 60 sec. The relative standard deviation w as 2.3% (n=5) for Cu(II) concentration of 10.0 ng/ml, with a limit of detec tion of 0.2 ng/ml. The influence of potentially interfering ions was comple tely studied. The method has been applied for the determination of Cu(II) i n wafer samples.