By-products NOx control and performance improvement of a packed-bed nonthermal plasma reactor

Citation
Jf. Xia et al., By-products NOx control and performance improvement of a packed-bed nonthermal plasma reactor, PLASMA CHEM, 20(2), 2000, pp. 225-233
Citations number
8
Categorie Soggetti
Physical Chemistry/Chemical Physics","Chemical Engineering
Journal title
PLASMA CHEMISTRY AND PLASMA PROCESSING
ISSN journal
02724324 → ACNP
Volume
20
Issue
2
Year of publication
2000
Pages
225 - 233
Database
ISI
SICI code
0272-4324(200006)20:2<225:BNCAPI>2.0.ZU;2-1
Abstract
NOx are main toxic by-products in the effluent gas when decomposing volatil e organic compounds in air by a packed-bed plasma reactor. Several types of materials such as 13X zeolite, BaTiO3 and Pd/Pt catalysts have been select ed to be packed in the reactor, and methane decomposition and NOx by-produc ts in discharged gases are investigated at different range of reaction temp erature and discharge energy density at atmospheric pressure. The ratios of methane decomposition percentage/NOx concentration are used to assess thes e packed bed materials and reaction conditions. The results show that using Pd/gamma-Al2O3 with lower percentage Pd as packed bed, and discharging wit h lower discharge density at higher reaction temperature can reduce NOx out put effectively and greatly improve performance of the reactor.