Aj. Bradley et al., TRANSVAGINAL LEAK OF PERITONEAL DIALYSATE DEMONSTRATED BY CT PERITONEOGRAPHY, British journal of radiology, 70(834), 1997, pp. 652-653
CT peritoneography is the investigation of choice for suspected leaks
or hernias in patients on continuous ambulatory peritoneal dialysis (C
APD). We report a case of transvaginal leak of peritoneal dialysate in
a young woman, confirmed by CT peritoneography. CAPD has been success
fully recommenced following the repair of a left vaginal vault erosion
.