H. Chiriac et al., Linear variable differential transformer sensor using glass-covered amorphous wires as active core, J MAGN MAGN, 215, 2000, pp. 759-761
Results concerning linear variable differential transformer (LVDT) displace
ment sensor using as movable core glass-covered amorphous wires are present
ed. The LVDT response is linear for a displacement of the movable core up t
o about 14 mm, with an accuracy of 1 mu m. LVDT using glass-covered amorpho
us wire as an active core presents a high sensitivity and good mechanical a
nd corrosion resistance. (C) 2000 Elsevier Science B.V. All rights reserved
.