G. Mazerolles et al., Moisture and fat content determination in hard and semi-hard cheeses by near infrared spectroscopy in transmission mode., LAIT, 80(3), 2000, pp. 371-379
Near infrared spectroscopy in transmission mode was used to analyse moistur
e and fat content in hard and semi-hard cheeses just after whey removing. I
n order to get a more reliable characterization of this method, experimenta
l cheeses with a large range of concentration and partly decorrelated in fa
t and moisture contents were manufactured. Different commercial cheeses col
lected in dairy factories were added to these samples. The results obtained
were: residual standard deviation of calibration (S-x,S-y) = 0.45 g.100 g(
-1) and standard error of prediction (S.E.P.)= 0.39 g.100 g(-1) for moistur
e; s(x,y) = 0.49 g.100 g(-1) and S.E.P. = 0.49 g.100 g(-1) for fat. Calibra
tion models use a relevant spectral information for each component. This ch
aracteristic allows to determine moisture and fat contents of cheeses from
different origins.