2,4,6-tri(3,5-dimethylpyrazoyl)-1,3,5-triazine modified carbon paste electrode for trace Cobalt(II) determination by differential pulse anodic stripping voltammetry

Citation
Xq. Lu et al., 2,4,6-tri(3,5-dimethylpyrazoyl)-1,3,5-triazine modified carbon paste electrode for trace Cobalt(II) determination by differential pulse anodic stripping voltammetry, TALANTA, 52(3), 2000, pp. 411-416
Citations number
8
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences
Journal title
TALANTA
ISSN journal
00399140 → ACNP
Volume
52
Issue
3
Year of publication
2000
Pages
411 - 416
Database
ISI
SICI code
0039-9140(20000630)52:3<411:2MCPE>2.0.ZU;2-O
Abstract
A differential pulse anodic stripping voltammetry was developed for the sen sitive and selective determination of Co(II) at 214.6-tri(3,5-dimethylpyraz oyl)-1.3.5-triazine modified carbon paste electrode in 0.1 mol l(-1) NH4Cl solution (pH 4.95). The oxidation peak of Co(II) was observed at 0.03 V(vs. Ag/AgCl) by scanning the potential in a positive direction. The analysis p rocedure consisted of an open circuit accumulation step in stirred sample s olution. This was followed by medium exchange to a clean solution and subse quently an anodic potential scan was effect to obtain the voltammetric peak . The current was proportional to the concentration of the Co(II) ion in a range of 1 x 10(-8)-1 x 10(-6) mol l(-1) for 3 min accumulation and in the range of 1 x 10(-9)-1 x 10(-8) mol l(-1) for 5 min accumulation; most of me tal ions do not interfere with the determination. The developed method was applied to Co(II) determination in potable water. (C) 2000 Elsevier Science B.V. All rights reserved.