Cs. Byun et al., Conceptual design and analysis of a semi-passive containment cooling system for a large concrete containment, NUCL ENG DE, 199(3), 2000, pp. 227-242
An internal evaporator-only (IEO) concept has been developed as a semi-pass
ive containment cooling system for a large dry concrete containment. The fu
nction of this system is to keep the containment integrity by maintaining t
he internal pressure not to exceed ultimate design pressure, i.e. 0.83 MPa
(120 psia) in the absence of any other containment cooling following a seve
re accident, which postulates core damage and hydrogen combustion. The abil
ity of the concept to protect the containment was evaluated for the design
basis accident (DBA) large break loss of coolant accident (LB LOCA) and sev
ere accident scenarios (LB LOCA without Emergency Core Cooling System (ECCS
) and containment spray flow, 100% zirconium oxidation and complete hydroge
n combustion). All were modeled using the GOTHIC computer code. It was conc
luded that a practical system requiring four IEO loops could be utilized to
meet design criteria for severe accident scenarios. (C) 2000 Elsevier Scie
nce S.A. All rights reserved.