H. Yamaguchi et al., ULTRASONIC FLAW DETECTION FOR HIGH IMPEDANCE MATERIALS USING A TRANSMISSION-LINE COUPLING METHOD, JPN J A P 1, 36(5B), 1997, pp. 3287-3289
A method for the detection of hidden flaws close to the surface of the
sample is described. The method uses a fused quartz rod coupled to th
e sample. The flaw is measured as a variation in the acoustic impedanc
e. The experimental detection of hidden flaws in glass and aluminum is
demonstrated.