The Rn dose conversion factor (DCF), which relates the effective dose to th
e exposure to the potential alpha energy concentration (PAEC) of inhaled Rn
progeny, was surveyed for 23 occupied and air-conditioned offices in Hong
Kong using the bronchial dosimeter for Rn progeny proposed by Yu and Guan i
n 1998. The mean values of PAEC deposited in the tracheobronchial region (P
AEC(T-B)), total PAEC in air (PAEC(T)) and the concentration of Rn (RC) for
the offices were 0.13 +/- 0.12 mWL, 3.4 +/- 3.3 mWL and 30 +/- 12 Bq m(-3)
, respectively, An average bronchial deposition fraction of Rn progeny was
obtained as 0.037 (range: 0.033-0.051), which gave a DCF of 9.5 (range: 8.4
-13) mSv WLM-1. The annual effective dose (E) was estimated to be 0.38 +/-
0.35 mSv yr(-1) for the offices. (C) 2000 Elsevier Science Ltd. All rights
reserved.