Solid-state electrochemical sensor devices combined with sodium super ionic conductor (NASICON: Na1+xZr2SixP3-xO12) discs and Pb-Ru-based pyrochlore-t ype oxide electrodes have been developed for the detection of NO and NO2 in the range 10-1000 ppm at 400 degrees C. Sensor devices fitted with pyrochl ore-type oxide electrodes showed good EMF responses to the sample gases con taining NO or NO2. EMFs were almost linear to the logarithm of NO or NO2 co ncentration, while the value and slope of the EMF responses were changed dr astically, depending on the electrode materials. Among the devices tested, the one attached to Pb2Ru1.9V0.1O7-z electrode gave the best response perfo rmance to NO and NO2, i.e., the 90% response time to 500 ppm NO or 110 ppm NO2 was as short as 30s or 1 min, respectively. (C) 2000 Elsevier Science S .A. All rights reserved.