Mc. Garcia-alonso et al., Influence of an acid pH and desoxygenation on the in vitro corrosion behaviour of preoxidised MA 956, B S ESP CER, 39(3), 2000, pp. 363-366
Citations number
10
Categorie Soggetti
Material Science & Engineering
Journal title
BOLETIN DE LA SOCIEDAD ESPANOLA DE CERAMICA Y VIDRIO
The lifetime of implants is affected by the aggressivity of the physiologic
al medium, which mainly results from the relatively high concentration of i
on chlorides. There are, however, other transient situations that may enhan
ce the aggressivity of the environment in the adjacent zones to the implant
. For example, during the first days of the implantation is rather frequent
to get bruises, inflammation, and even infections. These modifications cou
ld dramatically influence the corrosion behaviour and decrease the life exp
ectancy of the implant. In this work the corrosion behaviour of the MA 956,
which has been proposed as a new biomaterial, is investigated under experi
mental conditions of low pH and deareation, which simulate the most typical
medical complications in service.