Electroplated electro-fluidic interconnects for chemical sensors

Citation
Et. Enikov et Jg. Boyd, Electroplated electro-fluidic interconnects for chemical sensors, SENS ACTU-A, 84(1-2), 2000, pp. 161-164
Citations number
9
Categorie Soggetti
Instrumentation & Measurement
Journal title
SENSORS AND ACTUATORS A-PHYSICAL
ISSN journal
09244247 → ACNP
Volume
84
Issue
1-2
Year of publication
2000
Pages
161 - 164
Database
ISI
SICI code
0924-4247(20000801)84:1-2<161:EEIFCS>2.0.ZU;2-W
Abstract
A wet chip electro-fluidic packaging technology based on electroplating is described. An electroplated gold seal provides the sensor's fluid connectio n to a silicon multi-chip module. A hermetic seal is obtained using the gol d-silicon eutectic bond. The sensor's electrical connections to the multi-c hip module are made by eutectic bonding electroplated gold-tin solder bumps on the sensor to gold pads on the substrate. The fluid and electrical conn ections are made simultaneously, and the process is compatible with the fli p-chip bonding technique. (C) 2000 Elsevier Science S.A. All rights reserve d.