Dj. Weaver et al., Multilayer integrated-circuit imaging with contrast enhancement in a large-area, high-resolution electron-beam system, MICROEL ENG, 53(1-4), 2000, pp. 641-644
Electron-beam techniques and sample-preparation methods have been establish
ed to meet the requirements for imaging of complete integrated circuits to
determine the layout of each layer in the circuit and the layer-to-layer in
terconnections. Selective plating has been used to enhance contrast in back
scattered-electron images of metal layers and for via identification. Combi
ning a large-area imaging system with de-processing techniques and zinc ele
ctroless plating has given images with good discrimination between successi
ve layers in an integrated circuit, to permit the full reconstruction of th
e electrical connections of multi-layer integrated circuits including via c
ontacts.