A chemometric approach to spectral curve deconvolution is described, e
valuated, and applied to micellar systems. The technique is based on t
he method of principal component analysis of a spectral matrix followe
d by transformation of the abstract vectors into real spectra and conc
entrations. The approach reported here is similar to that of Kubista e
t al. (Anal. Chem. 1993, 65, 994-998). In the present study, however,
more spectral information is known about the system of interest. This
information is included in the deconvolution, which should, in general
, increase the reliability of the method. From this method we obtain v
ery reliable (noise-insensitive) lambda(max) values of indicator molec
ules in the micellar pseudophase free from contributions of the indica
tor in the aqueous phase. The water-to-micelle partition coefficients
are also determined. The effects of noise and the extent of indicator
partitioning on the reliability of the method are evaluated using mode
l data. The application of the method to the study of eight indicators
in a prototypical micellar system (sodium dodecyl sulfate) is present
ed. Extension of the method to other types of chemical studies such as
the determination of kinetic rate constants and product spectra is br
iefly discussed.