Erosion of tungsten coated tiles on the central column of ASDEX Upgrade

Citation
A. Tabasso et al., Erosion of tungsten coated tiles on the central column of ASDEX Upgrade, NUCL FUSION, 40(8), 2000, pp. 1441-1444
Citations number
5
Categorie Soggetti
Physics
Journal title
NUCLEAR FUSION
ISSN journal
00295515 → ACNP
Volume
40
Issue
8
Year of publication
2000
Pages
1441 - 1444
Database
ISI
SICI code
0029-5515(200008)40:8<1441:EOTCTO>2.0.ZU;2-V
Abstract
There are plans at ASDEX Upgrade to cover the heat shield of the inner main chamber wall with tungsten coated graphite tiles. Four tiles were installe d at different poloidal. positions of the heat shield and removed after a f ull experimental campaign. The tiles were analysed by means of Rutherford b ackscattering (RBS) analysis before insertion and by both RES and particle induced X ray emission after removal. This is an investigation of the poloi dal and toroidal erosion profiles on the tiles due to sputtering by charge exchange neutral and ion impact.