Gm. Florianovich et Vb. Makeev, On correctly using voltammetric measurements in evaluating free-corrosion rates of metals, PROT MET R, 36(4), 2000, pp. 375-379
Possible sources of the incorrectness in using the net anodic current densi
ty from a voltammetric curve for calculating the metal dissolution rate at
different potentials (according to Faradays law) are systematized. Such a s
ource may originate from commensurably intense side electrochemical process
es, salt deposition on the dissolving metal surface, high ohmic potential d
rops, etc. Ways to reveal and overcome conditions that complicate interpret
ing the results of voltammetric measurements are suggested.