In-line optical lever system for ultrasmall cantilever displacement detection

Citation
A. Kikukawa et al., In-line optical lever system for ultrasmall cantilever displacement detection, JPN J A P 1, 39(4A), 2000, pp. 1885-1889
Citations number
11
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Volume
39
Issue
4A
Year of publication
2000
Pages
1885 - 1889
Database
ISI
SICI code
Abstract
Cantilevers as small as 10 mu m in length are required in order to achieve a practical data transfer rate in a read-only memory system using cantileve rs as head. Thus, a new optical lever design concept that can detect the mo tion of such small cantilevers is necessary. The new optical lever concept that we propose makes it possible to use an objective lens with a high nume rical aperture and to reduce the expansion rate of the projected light sour ce image on the cantilever surface. As a result, we were able to reduce the incident laser spot diameter to 5 mu m. It was also possible to expand the operation bandwidth to 10 MHz while achieving a displacement sensitivity o f 0.48 Angstrom (when a 10-mu m long cantilever was used) by using a small spot position sensor, because the laser spot diameter on the detector could to be reduced to an arbitrary size.