We present a simple method for increasing the number of data points obtaine
d during performance of profilometric measurements with the Ronchi test. Th
e method is based on multiple ronchigram acquisitions that are superimposed
after a few very simple data-processing operations. The measurement method
, experimental setup, and data processing are described in detail from the
ronchigram to the measured profile, and experimental results for a concave
surface of an spherical ophthalmic lens are provided. The radius of curvatu
re values measured for that surface are compared with the ones obtained wit
h a high-precision radioscope, showing very good agreement and demonstratin
g capability of the technique to measure topographic profiles of reflective
samples. (C) 2000 Optical Society of America OCIS codes: 120.3930, 120.394
0, 120.4800, 120.6650, 120.4290.