High-gain power recycling of a Fabry-Perot Michelson interferometer for a gravitational-wave antenna

Citation
S. Sato et al., High-gain power recycling of a Fabry-Perot Michelson interferometer for a gravitational-wave antenna, APPL OPTICS, 39(25), 2000, pp. 4616-4620
Citations number
12
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Optics & Acoustics
Journal title
APPLIED OPTICS
ISSN journal
00036935 → ACNP
Volume
39
Issue
25
Year of publication
2000
Pages
4616 - 4620
Database
ISI
SICI code
0003-6935(20000901)39:25<4616:HPROAF>2.0.ZU;2-6
Abstract
Power recycling was implemented on a fully suspended prototype interferomet er with arm lengths of 20 m. A wave-front-sensing technique for alignment c ontrol of the suspended mirrors was also implemented, which allowed for sev eral hours of stable operation. A power-recycling gain of greater than 12 w as achieved, a significant increase over the highest gain in a suspended mi rror Fabry-Perot Michelson interferometer reported to date. (C) 2000 Optica l Society of America OCIS codes: 120.3180, 000.2780, 120.2230, 350.1270.